PX3 Series
- Type: Absolute, Gauge, Sealed Gauge
- Range: 0 ... 100 mbar to 0 ... 250 bar
- Accuracy: ≤ ±0.25 %FS, ≤ ±0.5 %FS, ≤ ±1 %FS
- Output: 4 ... 20 mA, 0 ... 10 VDC, 0 ... 5 VDC, 1 ... 5 VDC, 0.5 ... 4.5 VDC, 0.5 ... 4.5 VDC Ratiometric
Applications

Describtion
The PX3 Series pressure transmitters from Hogller are a robust, reliable, and accurate solution for a wide range of industrial applications. They are designed to meet the demands of demanding environments and provide precise pressure measurements for accurate pressure measurement. With their robust construction and long-lasting performance, the PX3 Series is a valuable asset for any industrial setting.
Key
Features
Unwavering Accuracy for Pressure Measurement
The PX3 Series pressure transmitters are renowned for their exceptional accuracy, ensuring precise and reliable pressure readings across a wide range of applications. The series offers a typical accuracy of ±0.5%FS, making it a highly sought-after choice for demanding industrial environments.
For applications requiring enhanced accuracy, the PX3 Series offers a ±0.25%FS option, available for pressure ranges under:
- 100 bar for gauge pressure transmitters
- 250 bar for absolute pressure transmitters
- 200 bar for compound pressure transmitters
This ultra-precise option ensures exceptional measurement accuracy in critical applications where exact pressure values are paramount.
Key Accuracy Parameters
- Non-linearity: The deviation of the actual pressure measurement from a perfectly linear relationship.
- Pressure Hysteresis: The difference between the high and low pressure readings over a defined pressure range.
Non-repeatability: The variation in pressure readings obtained from repeated measurements under identical conditions.
Total Error Band
The series offers a total error band of ±0.75%FS within the temperature range of 0 to 50℃ and ±1.25%FS within the temperature range of -10 to 80℃.
Key Total Error Band Parameters:
- Nonlinearity: The maximum deviation from a perfectly linear relationship across the operating temperature range.
- Hysteresis: The difference between the high and low pressure readings over a defined pressure range at a particular temperature.
- Repeatability: The variation in pressure readings obtained from repeated measurements under identical conditions and temperature.
- Temperature Effect: The change in pressure measurement due to temperature variations.
- Zero Thermal Error: The deviation of the pressure measurement from the true zero pressure at a particular temperature.
- Span Thermal Error: The change in the full-scale pressure range due to temperature variations.
Diverse Electrical Connection Options for Seamless Integration
The PX3 Series provides a range of flexible electrical connection options to seamlessly integrate with various applications and environments. The series’ typical electrical connection, the Angular Connector DIN 175301-803A, offers an ingress protection level of IP65, ensuring robust protection against dust and water ingress. Additionally, the series accommodates customer-specific requirements by offering additional electrical connections, including:
- Circular Aviation Plug M12×1(4pin): This connection provides IP65 or IP67 ingress protection, depending on customer preference.
- Cable connection: This connection with Φ5.0mm cable diameter made of Polyurethane offers IP67 ingress protection for demanding applications.
These versatile electrical connection options enable the PX3 Series to adapt to a wide range of industrial environments and seamlessly integrate into various control systems. Whether your application demands IP65 protection or the ruggedness of IP67, the PX3 Series ensures a secure and reliable electrical connection for your pressure measurement needs.
Seamless Installation for Reliable Measurement
The Hogller PX3 Series offer a user-friendly and straightforward installation process to ensure hassle-free integration into your industrial applications. The series typically features a G 1/4” A process connection, but it can also be customized to accommodate other connections, such as 1/4” NPT, R 1/4”, and more, based on specific customer requirements.
During installation and uninstallation, the maximum torque should be maintained within the range of 20N.m to 35N.m to prevent damage to the transmitter. To ensure optimal performance, the pressure port should be oriented vertically downward.
Unmatched Durability with Stainless Steel Enclosure
The PX3 Series boast a robust and durable enclosure crafted from stainless steel 316L, ensuring long-lasting performance in demanding industrial environments. The full-welded construction eliminates any potential leaks and ensures the integrity of the enclosure, making it resistant to corrosion and harsh conditions. This comprehensive stainless steel construction safeguards both internal diaphragm, process connection and housing, protecting them from environmental factors and ensuring precise pressure measurements even in challenging applications.
Unwavering Performance Over Time
The PX3 Series pressure transmitters exhibit exceptional long-term stability, ensuring precise pressure readings over extended periods of operation. The series boasts a typical long-term stability of ≤±0.1%FS/year and a maximum of ≤±0.2%FS/year, guaranteeing consistent performance and eliminating the need for frequent recalibrations.
Rapid Response for Real-time Measurement
This series features exceptional response times, ensuring rapid pressure measurements for real-time process control. The series delivers a response time of:
- Less than 4 ms for fluids with a viscosity of less than 100 cSt
- Less than 35 ms for gasses
This rapid response capacity minimizes measurement lag, allowing for prompt feedback and effective process adjustments, ensuring optimal system performance and efficient operation. Whether you’re monitoring rapid pressure fluctuations or conducting precise pressure measurements for precise control, the PX3 Series guarantees rapid response for real-time process control and dynamic applications.
Superior Sensitivity with Silicon Oil Transmission
This series employs silicon oil as the pressure transmission medium, ensuring exceptional sensitivity and accuracy in pressure measurement. This specialized oil effectively transmits the pressure applied to the internal diaphragm to the sensor chip, enabling precise pressure readings. The silicon oil’s stability and resistance to temperature fluctuations further enhance the accuracy and reliability of the pressure measurements.
Enduring Performance in Diverse Temperature Environments
The PX3 Series pressure transmitters from Hogller are designed to operate reliably in a wide range of temperature conditions, ensuring precise pressure measurements even in challenging environments:
- Medium Temperature: -30 … 85℃
- Environment Temperature: -30 … 85℃
- Storage Temperature: -40 … 100℃
The standard NBR sealing element can withstand this temperature range, making it an ideal choice for most applications. However, for applications requiring a FKM sealing element, the medium temperature range is reduced to -10 … 85℃. This accommodates the specific characteristics of FKM, ensuring long-lasting performance and reliable pressure readings under these temperature conditions.
Flexible Selections and Options
The PX3 Series pressure transmitters offer a wide range of versatile options to suit your specific needs and preferences. Whether you require a high-precision transmitter with ±0.25%FS accuracy or a robust and durable option with a stainless steel 316L enclosure, the PX3 Series has the perfect solution for you. With its diverse electrical connection options,the PX3 Series seamlessly integrates into various industrial environments and control systems. Additionally, the series accommodates multiple process connections, ensuring compatibility with your specific application requirements.
Why Choose Hogller PX3?
In a world of industrial pressure measurement solutions, the Hogller PX3 Series stands out as a beacon of excellence. Its unwavering accuracy, seamless installation process, unmatched durability, unwavering performance over time, rapid response time, and enduring performance in diverse temperature environments make it the ideal choice for a wide range of applications. When you choose the PX3 Series, you’re investing in a pressure measurement solution that is built to last, delivers exceptional performance, and ensures the accuracy and reliability you demand.
Our Specifications
Our Specifications
Feature | Value | Code |
---|---|---|
Pressure Type | Absolute | A |
Gauge | G | |
Sealed Gauge | S | |
Pressure Range | 0 … 250 | e.g. (0 … 250) |
Unit | mbar | kPa |
bar | MPa | |
psi | kgf/cm² | |
Power Supply | 5 ± 0.5 VDC | S05 |
8 ... 30 VDC | S08 | |
14 ... 30 VDC | S17 | |
Output Signal | 4 … 20 mA / 2-wire | C01 |
0 … 10 VDC / 3-wire | V01 | |
0 … 5 VDC / 3-wire | V03 | |
1 … 5 VDC / 3-wire | V04 | |
0.5 … 4.5 VDC / 3-wire | V07 | |
0.5 … 4.5 VDC Ratiometric / 3-wire | V08 | |
Accuracy | ≤ ±0.25 %FS | B2 |
≤ ±0.5 %FS | A5 | |
≤ ±1 %FS | A6 | |
Process Connection | G 1/8“ B, Male, std. EN 837 | 01 |
G 1/4“ B, Male, std. EN 837 | 02 | |
G 3/8“ B, Male, std. EN 837 | 03 | |
G 1/2“ B, Male, std. EN 837 | 04 | |
M20 x 1.5, Male, std. EN 837 | 05 | |
G 1/8“, Female, std. EN 837 | 06 | |
G 1/4“, Female, std. EN 837 | 07 | |
R 1/4“, Male, std. ISO 7 | 08 | |
R 3/8“, Male, std. ISO 7 | 09 | |
R 1/2“, Male, std. ISO 7 | 10 | |
G 1/4“, Female , std. ISO 1179-1 | 12 | |
G 1/4“ A, Male, std. ISO 1179-2 | 13 | |
G 3/8“ A, Male, std. ISO 1179-2 | 14 | |
G 1/2“ A, Male, std. ISO 1179-2 | 15 | |
M12 x 1.5, Male, std. ISO 9974-2 | 16 | |
M14 x 1.5, Male, std. ISO 9974-2 | 17 | |
M20 x 1.5, Male, std. ISO 9974-2 | 19 | |
1/8“ NPT, Male, std. ANSI/ASME B1.20.1 | 22 | |
1/4“ NPT, Male, std. ANSI/ASME B1.20.1 | 23 | |
1/2“ NPT, Male, std. ANSI/ASME B1.20.1 | 24 | |
1/8“ NPT, Female, std. ANSI/ASME B1.20.1 | 25 | |
1/4“ NPT, Female, std. ANSI/ASME B1.20.1 | 26 | |
1/2“ NPT, Female, std. ANSI/ASME B1.20.1 | 27 | |
7/16-20 UNF - 74°Taper Male, std. SAE J514 E | 28 | |
Snubber | Without Snubber | null |
With Snubber | S | |
Customized Pressure Channel | C | |
Electrical Connection | DIN EN 175301-803, Form A | D1 |
M12x1, 4-pin, Mat. Plastic | M1 | |
Cable Outlet, Mat. PUR | C2 | |
Extension Cable | Without Assorted Connector | null |
With Assorted Connector | B1 | |
Female Straight Connector M12x1, 4-pin Integrated with 2m Cable | B2 | |
Female Right Angle Connector M12x1, 4-pin Integrated with 2m Cable | B3 | |
n means cable length when electrical connection is C2 type (exc. L0 = 0.5 m) | Ln | |
Material | SS 304 Diaphragm, SS 304 Pressure Port, SS 316L Housing | 22 |
SS 316L Diaphragm, SS 316L Pressure Port, SS 316L Housing | 24 | |
Sealing Material | Without Seal | W |
NBR | N | |
FKM | F | |
Copper | C |
Stocked Products
Stocked Products
Products Part Number | Pressure Range | Output | Accuracy | Connection |
---|---|---|---|---|
PX3-G-(-100 … 100)mbar-C01-A6-13-D1-B1-N | -100 to 100 mbar | 4-20 mA | ≤±1 %FS | G 1/4“ A |
PX3-G-(0 … -1)bar-C01-A5-13-D1-B1-N | 0 to -1 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(-1 … 0)bar-C01-A5-13-D1-B1-N | -1 to 0 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(-1 … 1)bar-C01-A5-13-D1-B1-N | -1 to 1 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(-1 … 5)bar-C01-A5-13-D1-B1-N | -1 to 5 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(-1 … 9)bar-C01-A5-13-D1-B1-N | -1 to 9 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(-1 … 15)bar-C01-A5-13-D1-B1-N | -1 to 15 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(-1 … 24)bar-C01-A5-13-D1-B1-N | -1 to 24 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(-1 … 30)bar-C01-A5-13-D1-B1-N | -1 to 30 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(-1 … 35)bar-C01-A5-13-D1-B1-N | -1 to 35 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 100)mbar-C01-A6-13-D1-B1-N | 0 to 100 mbar | 4-20 mA | ≤±1 %FS | G 1/4“ A |
PX3-G-(0 … 250)mbar-C01-A5-13-D1-B1-N | 0 to 250 mbar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 400)mbar-C01-A5-13-D1-B1-N | 0 to 400 mbar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 600)mbar-C01-A5-13-D1-B1-N | 0 to 600 mbar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 1)bar-C01-A5-13-D1-B1-N | 0 to 1 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 1.6)bar-C01-A5-13-D1-B1-N | 0 to 1.6 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 2)bar-C01-A5-13-D1-B1-N | 0 to 2 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 2.5)bar-C01-A5-13-D1-B1-N | 0 to 2.5 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 4)bar-C01-A5-13-D1-B1-N | 0 to 4 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 6)bar-C01-A5-13-D1-B1-N | 0 to 6 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 7)bar-C01-A5-13-D1-B1-N | 0 to 7 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 10)bar-C01-A5-13-D1-B1-N | 0 to 10 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 15)bar-C01-A5-13-D1-B1-N | 0 to 15 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 16)bar-C01-A5-13-D1-B1-N | 0 to 16 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 18)bar-C01-A5-13-D1-B1-N | 0 to 18 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 20)bar-C01-A5-13-D1-B1-N | 0 to 20 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 25)bar-C01-A5-13-D1-B1-N | 0 to 25 bar | 4-20 mA | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 1)bar-V01-A5-13-D1-B1-N | 0 to 1 bar | 0-10 V | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 4)bar-V01-A5-13-D1-B1-N | 0 to 4 bar | 0-10 V | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 6)bar-V01-A5-13-D1-B1-N | 0 to 6 bar | 0-10 V | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 10)bar-V01-A5-13-D1-B1-N | 0 to 10 bar | 0-10 V | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 10)bar-V03-A5-13-D1-B1-N | 0 to 10 bar | 0-5 V | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 16)bar-V01-A5-13-D1-B1-N | 0 to 16 bar | 0-10 V | ≤±0.5 %FS | G 1/4“ A |
PX3-G-(0 … 25)bar-V01-A5-13-D1-B1-N | 0 to 25 bar | 0-10 V | ≤±0.5 %FS | G 1/4“ A |
PX3-S-(0 … 40)bar-V01-A5-13-D1-B1-N | 0 to 40 bar | 0-10 V | ≤±0.5 %FS | G 1/4“ A |
PX3-S-(0 … 100)bar-V01-A5-13-D1-B1-N | 0 to 100 bar | 0-10 V | ≤±0.5 %FS | G 1/4“ A |
PX3-S-(0 … 160)bar-V01-A5-13-D1-B1-N | 0 to 160 bar | 0-10 V | ≤±0.5 %FS | G 1/4“ A |
PX3-S-(0 … 250)bar-V01-A5-13-D1-B1-N | 0 to 250 bar | 0-10 V | ≤±0.5 %FS | G 1/4“ A |
Downloads
Datasheets
Hogller PX3 Series Datasheet (EN)
Requests
Catalogs
Related Solutions
Related Solutions
Related Series
Related Series
- Type: Absolute, Gauge, Sealed Gauge
- Range: -1...0 to -1...60 bar, 0...350 mbar to 0...1000 bar
- Accuracy: ≤ ±0.5 %FS
- Absolute, Gauge, Sealed Gauge
- -1 ... 0 bar to 0 ... 1000 bar
- ±0.25 %FS, ±0.5 %FS, ±1 %FS