PX5 Series
- Type: Absolute, Gauge, Sealed Gauge
- Range: -1 ... 0 bar to 0 ... 1000 bar
- Accuracy: ±0.25 %FS, ±0.5 %FS, ±1 %FS
- Output: 4 ... 20 mA, 0 ... 10 VDC, 0 ... 5 VDC, 1 ... 5 VDC, 0.5 ... 2.5 VDC, 0.5 ... 4.5 VDC, 0.5 ... 4.5 VDC Ratiometric
Applications
Hydraulics and pneumatics, Food and beverage manufacturing, Energy management systems, Petroleum and petrochemical industry, Hydrology and water resources, Pressure monitoring in the hazardous areas, Engine manufacturing, Petrol/gasoline pressure measurement
Describtion
The Hogller PX5 pressure transmitter is a remarkable piece of engineering, boasting exceptional accuracy and unwavering reliability. Its innovative flush diaphragm design, high-quality materials, and sophisticated circuitry ensure precise measurements even under challenging conditions. Whether you’re monitoring low-pressure applications or dealing with extreme pressures, the PX5 is the ideal choice for demanding industrial environments.
Key
Features
Flush Diaphragm Design
The Hogller PX5 pressure transmitter stands out with its innovative flush diaphragm design. The flush diaphragm eliminates the dead volume, which is the unused space between the diaphragm and the pressure port. This design minimizes the potential for contamination and improves the response time of the transmitter. Additionally, the flush diaphragm provides a more accurate measurement.
The PX5’s flush diaphragm design also features a high-quality SS316L material, which is resistant to corrosion and harsh chemicals. This ensures the long-term durability and reliability of the transmitter, even in challenging industrial environments.
Unwavering Accuracy
Pressure Range | Accuracy |
---|---|
0…100 mbar to 200 mbar | ≤ ± 1% FS |
200 mbar to 1 bar | ≤ ± 0.5% FS |
1 bar to 35 bar | ≤ ± 0.25% FS, ≤ ± 0.5% FS |
Pressure Range | Accuracy |
---|---|
-1…-350 mbar to 2 bar | ≤ ± 1% FS |
-1…-350 mbar to 2…35 bar | ≤ ± 0.5% FS |
Pressure Range | Accuracy |
---|---|
0…700 mbar to 1 bar | ≤ ± 1% FS |
1 to 10 bar | ≤ ± 0.5% FS |
10 to 1000 bar | ≤ ± 0.25% FS, ≤ ± 0.5% FS |
Pressure Range | Accuracy |
---|---|
0…35 bar to 1000 bar | ≤ ± 0.25% FS, ≤ ± 0.5% FS |
Maintaining Accuracy Amidst Temperature Fluctuations
The Hogller PX5 pressure transmitter excels in maintaining accuracy even when subjected to temperature variations. Its zero thermal drift, which is the change in the zero point of the transmitter with temperature, is remarkably low:
- ±0.05%FS/℃ for pressures up to 1 bar
- ±0.03%FS/℃ for higher pressures
This means that the pressure reading remains consistent even as the ambient temperature changes, ensuring reliable measurements in dynamic environments.
Similarly, the PX5’s span thermal drift, which is the change in the full-scale span of the transmitter with temperature, also exhibits exceptional stability:
- ±0.05%FS/℃ for pressures up to 1 bar
- ±0.03%FS/℃ for higher pressures
This ensures that the transmitter accurately reflects the actual pressure across a wide range of temperatures.
Enduring Reliability
The Hogller PX5 pressure transmitter stands out not only for its exceptional accuracy but also for its unwavering stability over time. With an industry-leading long-term stability of ±0.3% FS/year, the PX5 ensures consistent and reliable data acquisition for extended periods.
The PX5’s long-term stability is a testament to Hogller’s commitment to delivering exceptional performance and reliability. Whether you’re monitoring pressure fluctuations in critical applications or implementing long-term data collection, the PX5 ensures unwavering accuracy and confidence in your measurements.
Unwavering Performance Under Pressure
The PX5 pressure transmitter boasts exceptional overpressure resistance, ensuring its resilience in demanding industrial environments. With an impressive overpressure rating of 2 times FS (Full Scale) or 1100 bar, whichever is lower, the PX5 withstands extreme pressure surges without compromising its performance or integrity. This robust design allows the PX5 to operate reliably in challenging applications where fluctuations and sudden pressure spikes are common
Temperature Considerations
The Hogller PX5 pressure transmitter demonstrates remarkable versatility in its ability to operate within a wide range of thermal conditions. The specific temperature specifications depend on the chosen electrical connection type:
Angular Connector DIN 175301-803A and Circular Aviation Plug M12×1(4pin):
- Operation Temperature: -30…80℃
- Storage Temperature: -40…120℃
These connection types are well-suited for applications where the temperature fluctuates within a broader range. Their robust design enables them to withstand temperature extremes while maintaining consistent performance.
Cable Connection:
The operation temperature of the cable connection varies depending on the cable material. PE and PVC cables are suitable for applications with moderate temperature fluctuations, while PUR cables are designed for higher operating temperatures:
- PE, PVC cable: -20℃ ~ 70℃
- PUR cable: -20℃ ~ 80℃
The storage temperature for cable connection is -20℃~85℃ despite the cable material.
Regardless of the connection type, the PX5 maintains consistent performance within the compensation temperature range of 0℃~50℃.
Flexible Selections and Options
Whether you’re monitoring low-pressure applications or dealing with extreme pressures, the PX5’s wide pressure range, including vacuum and compound pressure ranges, ensures you have the right tool for the job. And with its variety of electrical connection types, the PX5 can be seamlessly integrated into any industrial setting. Whether you need a robust transmitter for demanding environments or a precise instrument for critical applications, the Hogller PX5 is the perfect choice for your needs
Why Choose Hogller PX5?
Seeking precision measurement and a robust transmitter? Look no further than the Hogller PX5, featuring a revolutionary flush diaphragm design and the durability of SS316L material. Its incredible accuracy, ranging from ±0.25% FS to ±1% FS, ensures the reliability of your pressure readings. With a comprehensive range of pressure options, from vacuum to extreme pressures, the PX5 is the ideal choice for any industrial application. Elevate your precision measurement needs with the Hogller PX5 and experience the difference!
Our Specifications
Our Specifications
Feature | Value | Code |
---|---|---|
Pressure Type | Absolute | A |
Gauge | G | |
Sealed Gauge | S | |
Pressure Range | 0 … 250 | e.g. (0 … 250) |
Unit | mbar | kPa |
bar | MPa | |
psi | kgf/cm² | |
Power Supply | 3.3 ± 0.1 VDC | S01 |
5 ± 0.1 VDC | S04 | |
11 … 28 VDC | S13 | |
15 … 28 VDC | S18 | |
Output Signal | 4 … 20 mA / 2-wire | C01 |
0 … 10 VDC / 3-wire | V01 | |
0 … 5 VDC / 3-wire | V03 | |
1 … 5 VDC / 3-wire | V04 | |
0.5 … 2.5 VDC / 3-wire | V06 | |
0.5 … 4.5 VDC / 3-wire | V07 | |
Accuracy | ≤ ±0.25 %FS | B2 |
≤ ±0.5 %FS | A5 | |
≤ ±1 %FS | A6 | |
Structure | Membrane Inside | null |
Flush Membrane | F | |
Process Connection | M20 x 1.5, Male, std. EN 837 | 05 |
G 1/4“ A, Male, std. ISO 1179-2 | 13 | |
G 1/2“ A, Male, std. ISO 1179-2 | 15 | |
M20 x 1.5, Male, std. ISO 9974-2 | 19 | |
1/4“ NPT, Male, std. ANSI/ASME B1.20.1 | 23 | |
Clamp DN25 | C1 | |
Clamp DN25 with Heat Sink | C2 | |
Snubber | Without Snubber | null |
With Snubber | S | |
Customized Pressure Channel | C | |
Electrical Connection | DIN EN 175301-803, Form A | D1 |
M12x1, 4-pin, Mat. Steel | M2 | |
Cable Outlet, Mat. PE | C0 | |
Cable Outlet, Mat. PVC | C1 | |
Cable Outlet, Mat. PUR | C2 | |
Cable Outlet with Conduit Connection | C6 | |
Extension Cable | Without Assorted Connector | null |
With Assorted Connector | B1 | |
Female Straight Connector M12x1, 4-pin Integrated with 2m Cable | B2 | |
Female Right Angle Connector M12x1, 4-pin Integrated with 2m Cable | B3 | |
n means cable length when electrical connection is C type (exc. L0 = 0.5 m) | Ln | |
Material | SS 316L Diaphragm, SS 304 Pressure Port, SS 304 Housing | 42 |
SS 316L Diaphragm, SS 316L Pressure Port, SS 304 Housing | 43 | |
SS 316L Diaphragm, SS 316L Pressure Port, SS 316L Housing | 44 | |
Tantalum Diaphragm, SS 304 Pressure Port, SS 304 Housing | T2 | |
Tantalum Diaphragm, Hastelloy C Pressure Port, SS 304 Housing | TH | |
Sealing Material | Without Seal | W |
FKM | F | |
EPDM | E | |
Display Indicator | Without Display Indicator | null |
4 digits LED Digital Indicator | Z4 | |
4 digits LCD Digital Indicator | Z5 | |
Certification Requirement | No Certification Requirement | null |
ATEX | AT | |
Intrinsically safe type, Ex ia IIC T6 Ga | XI | |
Explosion-proof type, Ex d IIC T6 Ga | XD | |
Marine Approval | MA |
Stocked Products
Stocked Products
Part Number | Pressure Range | Output Signal | Accuracy | Process Connection |
---|---|---|---|---|
PX5-G-(0 … 100)mbar-S13-C01-F-15-D1-B1-44 | (0 … 100) mbar | 4 … 20 mA / 2-wire | ≤±1 %FS | G 1/2“ A, Male, std. ISO 1179-2 * |
PX5-G-(0 … 250)mbar-S13-C01-F-15-D1-B1-44 | (0 … 250) mbar | 4 … 20 mA / 2-wire | ≤±1 %FS | G 1/2“ A, Male, std. ISO 1179-2 * |
PX5-G-(0 … 400)mbar-S13-C01-F-15-D1-B1-44 | (0 … 400) mbar | 4 … 20 mA / 2-wire | ≤±0.5 %FS | G 1/2“ A, Male, std. ISO 1179-2 * |
PX5-G-(0 … 600)mbar-S13-C01-F-15-D1-B1-44 | (0 … 600) mbar | 4 … 20 mA / 2-wire | ≤±0.5 %FS | G 1/2“ A, Male, std. ISO 1179-2 * |
PX5-G-(0 … 1)bar-S13-C01-F-15-D1-B1-44 | (0 … 1) bar | 4 … 20 mA / 2-wire | ≤±0.5 %FS | G 1/2“ A, Male, std. ISO 1179-2 * |
PX5-G-(0 … 2.5)bar-S13-C01-F-15-D1-B1-44 | (0 … 2.5) bar | 4 … 20 mA / 2-wire | ≤±0.5 %FS | G 1/2“ A, Male, std. ISO 1179-2 * |
PX5-G-(0 … 4)bar-S13-C01-F-15-D1-B1-44 | (0 … 4) bar | 4 … 20 mA / 2-wire | ≤±0.5 %FS | G 1/2“ A, Male, std. ISO 1179-2 * |
PX5-G-(0 … 6)bar-S13-C01-F-15-D1-B1-44 | (0 … 6) bar | 4 … 20 mA / 2-wire | ≤±0.5 %FS | G 1/2“ A, Male, std. ISO 1179-2 * |
PX5-G-(0 … 10)bar-S13-C01-F-15-D1-B1-44 | (0 … 10) bar | 4 … 20 mA / 2-wire | ≤±0.5 %FS | G 1/2“ A, Male, std. ISO 1179-2 * |
PX5-G-(0 … 16)bar-S13-C01-F-15-D1-B1-44 | (0 … 16) bar | 4 … 20 mA / 2-wire | ≤±0.5 %FS | G 1/2“ A, Male, std. ISO 1179-2 * |
PX5-G-(0 … 25)bar-S13-C01-F-15-D1-B1-44 | (0 … 25) bar | 4 … 20 mA / 2-wire | ≤±0.5 %FS | G 1/2“ A, Male, std. ISO 1179-2 * |
PX5-G-(0 … 40)bar-S13-C01-F-15-D1-B1-44 | (0 … 40) bar | 4 … 20 mA / 2-wire | ≤±0.5 %FS | G 1/2“ A, Male, std. ISO 1179-2 * |
PX5-G-(0 … 100)bar-S13-C01-F-15-D1-B1-44 | (0 … 100) bar | 4 … 20 mA / 2-wire | ≤±0.5 %FS | G 1/2“ A, Male, std. ISO 1179-2 * |
PX5-G-(0 … 250)bar-S13-C01-F-15-D1-B1-44 | (0 … 250) bar | 4 … 20 mA / 2-wire | ≤±0.5 %FS | G 1/2“ A, Male, std. ISO 1179-2 * |
PX5-G-(0 … 400)bar-S13-C01-F-15-D1-B1-44 | (0 … 400) bar | 4 … 20 mA / 2-wire | ≤±0.5 %FS | G 1/2“ A, Male, std. ISO 1179-2 * |
Downloads
Related Solutions
Related Solutions
Related Series
Related Series
- Type: Absolute, Gauge, Sealed Gauge
- Range: 0 ... 100 mbar to 0 ... 250 bar
- Accuracy: ≤ ±0.25 %FS, ≤ ±0.5 %FS, ≤ ±1 %FS
- Type: Absolute, Gauge, Sealed Gauge
- Range: -1...0 to -1...60 bar, 0...350 mbar to 0...1000 bar
- Accuracy: ≤ ±0.5 %FS
- Material: Stainless Steel 304
- Process Connection: G 1/4" Male
- Instrument Connection: G 1/4" Female