Applications

Hydraulics and pneumatics, Food and beverage manufacturing, Energy management systems, Petroleum and petrochemical industry, Hydrology and water resources, Pressure monitoring in the hazardous areas, Engine manufacturing, Petrol/gasoline pressure measurement

CE/ROHS

Describtion

The Hogller PX5 pressure transmitter is a remarkable piece of engineering, boasting exceptional accuracy and unwavering reliability. Its innovative flush diaphragm design, high-quality materials, and sophisticated circuitry ensure precise measurements even under challenging conditions. Whether you’re monitoring low-pressure applications or dealing with extreme pressures, the PX5 is the ideal choice for demanding industrial environments.

Key

Features

Flush Diaphragm Design

The Hogller PX5 pressure transmitter stands out with its innovative flush diaphragm design. The flush diaphragm eliminates the dead volume, which is the unused space between the diaphragm and the pressure port. This design minimizes the potential for contamination and improves the response time of the transmitter. Additionally, the flush diaphragm provides a more accurate measurement.

The PX5’s flush diaphragm design also features a high-quality SS316L material, which is resistant to corrosion and harsh chemicals. This ensures the long-term durability and reliability of the transmitter, even in challenging industrial environments.

The Hogller PX5 pressure transmitter stands out from the crowd with its exceptional accuracy, catering to a wide range of industrial applications. Its precise measurements ensure reliable and consistent data, enabling informed decision-making in critical processes. To fully appreciate the impressive accuracy of this series, let’s delve into the specifics. All accuracy values are referenced to an environmental temperature of 20℃ ± 5℃. Maintaining a stable ambient temperature is crucial for ensuring the highest precision. Any significant deviations from this range may slightly impact the accuracy, but the PX5 remains remarkably consistent across a broad temperature spectrum. Accuracy Variations Based on Reference Pressure Type The accuracy of the PX5 pressure transmitter varies depending on the chosen reference pressure type:
Gauge Pressure Transmitters:
Pressure RangeAccuracy
0…100 mbar to 200 mbar≤ ± 1% FS
200 mbar to 1 bar≤ ± 0.5% FS
1 bar to 35 bar≤ ± 0.25% FS, ≤ ± 0.5% FS
Compound Pressure Pressure Transmitters:
Pressure RangeAccuracy
-1…-350 mbar to 2 bar≤ ± 1% FS
-1…-350 mbar to 2…35 bar≤ ± 0.5% FS
Absolute Pressure Transmitters:
Pressure RangeAccuracy
0…700 mbar to 1 bar≤ ± 1% FS
1 to 10 bar≤ ± 0.5% FS
10 to 1000 bar≤ ± 0.25% FS, ≤ ± 0.5% FS
Sealed Gauge Pressure Transmitters:
Pressure RangeAccuracy
0…35 bar to 1000 bar≤ ± 0.25% FS, ≤ ± 0.5% FS
These accuracy specifications highlight the PX5’s remarkable precision across a diverse range of pressure ranges and reference pressure types. Whether you’re monitoring low-pressure applications or dealing with extreme pressures, the PX5 ensures unwavering accuracy for critical data acquisition.

The Hogller PX5 pressure transmitter excels in maintaining accuracy even when subjected to temperature variations. Its zero thermal drift, which is the change in the zero point of the transmitter with temperature, is remarkably low:

  • ±0.05%FS/℃ for pressures up to 1 bar
  • ±0.03%FS/℃ for higher pressures

This means that the pressure reading remains consistent even as the ambient temperature changes, ensuring reliable measurements in dynamic environments.

Similarly, the PX5’s span thermal drift, which is the change in the full-scale span of the transmitter with temperature, also exhibits exceptional stability:

  • ±0.05%FS/℃ for pressures up to 1 bar
  • ±0.03%FS/℃ for higher pressures

This ensures that the transmitter accurately reflects the actual pressure across a wide range of temperatures.

The Hogller PX5 pressure transmitter stands out not only for its exceptional accuracy but also for its unwavering stability over time. With an industry-leading long-term stability of ±0.3% FS/year, the PX5 ensures consistent and reliable data acquisition for extended periods.

The PX5’s long-term stability is a testament to Hogller’s commitment to delivering exceptional performance and reliability. Whether you’re monitoring pressure fluctuations in critical applications or implementing long-term data collection, the PX5 ensures unwavering accuracy and confidence in your measurements.

The PX5 pressure transmitter boasts exceptional overpressure resistance, ensuring its resilience in demanding industrial environments. With an impressive overpressure rating of 2 times FS (Full Scale) or 1100 bar, whichever is lower, the PX5 withstands extreme pressure surges without compromising its performance or integrity. This robust design allows the PX5 to operate reliably in challenging applications where fluctuations and sudden pressure spikes are common

The Hogller PX5 pressure transmitter demonstrates remarkable versatility in its ability to operate within a wide range of thermal conditions. The specific temperature specifications depend on the chosen electrical connection type:

Angular Connector DIN 175301-803A and Circular Aviation Plug M12×1(4pin):

  • Operation Temperature: -30…80℃
  • Storage Temperature: -40…120℃

These connection types are well-suited for applications where the temperature fluctuates within a broader range. Their robust design enables them to withstand temperature extremes while maintaining consistent performance.

Cable Connection:

The operation temperature of the cable connection varies depending on the cable material. PE and PVC cables are suitable for applications with moderate temperature fluctuations, while PUR cables are designed for higher operating temperatures:

  • PE, PVC cable: -20℃ ~ 70℃
  • PUR cable: -20℃ ~ 80℃

The storage temperature for cable connection is -20℃~85℃ despite the cable material.

Regardless of the connection type, the PX5 maintains consistent performance within the compensation temperature range of 0℃~50℃.

Flexible Selections and Options

Whether you’re monitoring low-pressure applications or dealing with extreme pressures, the PX5’s wide pressure range, including vacuum and compound pressure ranges, ensures you have the right tool for the job. And with its variety of electrical connection types, the PX5 can be seamlessly integrated into any industrial setting. Whether you need a robust transmitter for demanding environments or a precise instrument for critical applications, the Hogller PX5 is the perfect choice for your needs

Why Choose Hogller PX5?

Seeking precision measurement and a robust transmitter? Look no further than the Hogller PX5, featuring a revolutionary flush diaphragm design and the durability of SS316L material. Its incredible accuracy, ranging from ±0.25% FS to ±1% FS, ensures the reliability of your pressure readings. With a comprehensive range of pressure options, from vacuum to extreme pressures, the PX5 is the ideal choice for any industrial application. Elevate your precision measurement needs with the Hogller PX5 and experience the difference!

Our Specifications

Our Specifications

FeatureValueCode
Pressure TypeAbsoluteA
GaugeG
Sealed GaugeS
Pressure Range0 … 250e.g. (0 … 250)
UnitmbarkPa
barMPa
psikgf/cm²
Power Supply3.3 ± 0.1 VDCS01
5 ± 0.1 VDCS04
11 … 28 VDCS13
15 … 28 VDCS18
Output Signal4 … 20 mA / 2-wireC01
0 … 10 VDC / 3-wireV01
0 … 5 VDC / 3-wireV03
1 … 5 VDC / 3-wireV04
0.5 … 2.5 VDC / 3-wireV06
0.5 … 4.5 VDC / 3-wireV07
Accuracy≤ ±0.25 %FSB2
≤ ±0.5 %FSA5
≤ ±1 %FSA6
StructureMembrane Insidenull
Flush MembraneF
Process ConnectionM20 x 1.5, Male, std. EN 83705
G 1/4“ A, Male, std. ISO 1179-213
G 1/2“ A, Male, std. ISO 1179-215
M20 x 1.5, Male, std. ISO 9974-219
1/4“ NPT, Male, std. ANSI/ASME B1.20.123
Clamp DN25C1
Clamp DN25 with Heat SinkC2
SnubberWithout Snubbernull
With SnubberS
Customized Pressure ChannelC
Electrical ConnectionDIN EN 175301-803, Form AD1
M12x1, 4-pin, Mat. SteelM2
Cable Outlet, Mat. PEC0
Cable Outlet, Mat. PVCC1
Cable Outlet, Mat. PURC2
Cable Outlet with Conduit ConnectionC6
Extension CableWithout Assorted Connectornull
With Assorted ConnectorB1
Female Straight Connector M12x1, 4-pin Integrated with 2m CableB2
Female Right Angle Connector M12x1, 4-pin Integrated with 2m CableB3
n means cable length when electrical connection is C type (exc. L0 = 0.5 m)Ln
MaterialSS 316L Diaphragm, SS 304 Pressure Port, SS 304 Housing42
SS 316L Diaphragm, SS 316L Pressure Port, SS 304 Housing43
SS 316L Diaphragm, SS 316L Pressure Port, SS 316L Housing44
Tantalum Diaphragm, SS 304 Pressure Port, SS 304 HousingT2
Tantalum Diaphragm, Hastelloy C Pressure Port, SS 304 HousingTH
Sealing MaterialWithout SealW
FKMF
EPDME
Display IndicatorWithout Display Indicatornull
4 digits LED Digital IndicatorZ4
4 digits LCD Digital IndicatorZ5
Certification RequirementNo Certification Requirementnull
ATEXAT
Intrinsically safe type, Ex ia IIC T6 GaXI
Explosion-proof type, Ex d IIC T6 GaXD
Marine ApprovalMA

Stocked Products

Stocked Products

Part NumberPressure RangeOutput SignalAccuracyProcess Connection
PX5-G-(0 … 100)mbar-S13-C01-F-15-D1-B1-44(0 … 100) mbar4 … 20 mA / 2-wire≤±1 %FSG 1/2“ A, Male, std. ISO 1179-2 *
PX5-G-(0 … 250)mbar-S13-C01-F-15-D1-B1-44(0 … 250) mbar4 … 20 mA / 2-wire≤±1 %FSG 1/2“ A, Male, std. ISO 1179-2 *
PX5-G-(0 … 400)mbar-S13-C01-F-15-D1-B1-44(0 … 400) mbar4 … 20 mA / 2-wire≤±0.5 %FSG 1/2“ A, Male, std. ISO 1179-2 *
PX5-G-(0 … 600)mbar-S13-C01-F-15-D1-B1-44(0 … 600) mbar4 … 20 mA / 2-wire≤±0.5 %FSG 1/2“ A, Male, std. ISO 1179-2 *
PX5-G-(0 … 1)bar-S13-C01-F-15-D1-B1-44(0 … 1) bar4 … 20 mA / 2-wire≤±0.5 %FSG 1/2“ A, Male, std. ISO 1179-2 *
PX5-G-(0 … 2.5)bar-S13-C01-F-15-D1-B1-44(0 … 2.5) bar4 … 20 mA / 2-wire≤±0.5 %FSG 1/2“ A, Male, std. ISO 1179-2 *
PX5-G-(0 … 4)bar-S13-C01-F-15-D1-B1-44(0 … 4) bar4 … 20 mA / 2-wire≤±0.5 %FSG 1/2“ A, Male, std. ISO 1179-2 *
PX5-G-(0 … 6)bar-S13-C01-F-15-D1-B1-44(0 … 6) bar4 … 20 mA / 2-wire≤±0.5 %FSG 1/2“ A, Male, std. ISO 1179-2 *
PX5-G-(0 … 10)bar-S13-C01-F-15-D1-B1-44(0 … 10) bar4 … 20 mA / 2-wire≤±0.5 %FSG 1/2“ A, Male, std. ISO 1179-2 *
PX5-G-(0 … 16)bar-S13-C01-F-15-D1-B1-44(0 … 16) bar4 … 20 mA / 2-wire≤±0.5 %FSG 1/2“ A, Male, std. ISO 1179-2 *
PX5-G-(0 … 25)bar-S13-C01-F-15-D1-B1-44(0 … 25) bar4 … 20 mA / 2-wire≤±0.5 %FSG 1/2“ A, Male, std. ISO 1179-2 *
PX5-G-(0 … 40)bar-S13-C01-F-15-D1-B1-44(0 … 40) bar4 … 20 mA / 2-wire≤±0.5 %FSG 1/2“ A, Male, std. ISO 1179-2 *
PX5-G-(0 … 100)bar-S13-C01-F-15-D1-B1-44(0 … 100) bar4 … 20 mA / 2-wire≤±0.5 %FSG 1/2“ A, Male, std. ISO 1179-2 *
PX5-G-(0 … 250)bar-S13-C01-F-15-D1-B1-44(0 … 250) bar4 … 20 mA / 2-wire≤±0.5 %FSG 1/2“ A, Male, std. ISO 1179-2 *
PX5-G-(0 … 400)bar-S13-C01-F-15-D1-B1-44(0 … 400) bar4 … 20 mA / 2-wire≤±0.5 %FSG 1/2“ A, Male, std. ISO 1179-2 *

Downloads

Datasheets

Hogller PX5 Series Datasheet (EN)

Related
Solutions

Related
Solutions

Ensure vessel stability with advanced pressure transmitters for accurate ballast tank level monitoring in the maritime industry. Prevent accidents and optimize buoyancy with reliable digital data integration.
Enhance groundwater management with pressure transmitters for real-time monitoring. Gain crucial insights and improve sustainability with advanced groundwater monitoring solutions.
Improve wastewater treatment efficiency with pressure transmitters for real-time flow and level control. Enhance accuracy and optimize operations with advanced monitoring solutions.

Related
Series

Related
Series

Contact Us Today

To learn more about the Hogller PX1 series pressure transmitter or to request a quote, please contact us today.

PX5 Series