PX4 Series

Applications

Machine tools, Hydraulics and pneumatics, Plant control and monitoring, Refrigeration systems, Pumps and compressors control, Energy management systems, HVAC systems

CE/ROHS

Describtion

The Hogller PX4 Pressure Transmitter is a robust and reliable pressure transmitter engineered to withstand demanding industrial applications. With its exceptional overpressure and burst pressure resistance, unparalleled vibration and shock resistance, and robust all-metal sealing structure, the PX4 Pressure Transmitter delivers accurate and reliable pressure measurements in extreme environments.

Key

Features

Unmatched Overpressure and Burst Pressure Resistance

The PX4 Pressure Transmitter from Hogller features an advanced micro-fused technology that enables it to withstand extreme overpressure and burst pressure conditions. This technology is responsible for the transmitter’s ability to withstand up to 3xFS of overpressure, ensuring its reliability and safety in demanding applications This exceptional performance is achieved without compromising the transmitter’s accuracy and reliability.

Overpressure Resistance:

  • For pressure ranges up to 50 bar: 3xFS
  • For pressure ranges of 50 to 750 bar: 2xFS
  • For pressure ranges of 750 to 1000 bar: 1.5xFS

Burst Pressure:

  • ≤ 5xFS (maximum of 2000 bar for pressure ranges greater than 400 bar)

The Hogller PX4 Pressure Transmitter is designed to withstand harsh environments, featuring exceptional vibration and shock resistance. It can tolerate a 20 g vibration within the frequency range of 20 Hz to 2000 Hz, ensuring its resilience in demanding applications. 

The PX4 Pressure Transmitter also excels in shock resistance, capable of withstanding a 100 g shock with a duration of 6 ms. This exceptional shock resistance safeguards the transmitter from sudden impacts and abrupt pressure fluctuations, ensuring its reliable operation even in the most challenging environments.

The PX4 Pressure Transmitter’s unwavering performance under vibration and shock conditions is a testament to its exceptional design and engineering. These features make it an ideal choice for applications where the transmitter is exposed to harsh environments and sudden impacts.

The PX4 series pressure transmitter leverages a non-oil-filled design, eliminating the need for an internal sealing ring, thereby enhancing its reliability, simplifying maintenance, and expanding its compatibility with various applications. The wetted parts of the transmitter are meticulously crafted from stainless steel 17-4PH, a corrosion-resistant material that ensures the accuracy of pressure transmission. The isolation diaphragm, likewise, is made from the same material, maintaining pressure signal integrity.

The lack of oil filling in the transmitter eliminates the risk of oil leakage and contamination, further enhancing its reliability and safety. This all-metal sealing structure, coupled with the use of high-grade stainless steel materials, makes the PX4 Pressure Transmitter an ideal choice for applications where extreme environmental conditions and prolonged exposure to corrosive substances are a concern.

The PX4 pressure transmitter features a dual reference pressure setup, catering to the specific needs of applications with different measuring ranges.

  • For pressure ranges ≤ 3.5 MPa, the transmitter employs a vented gauge, ensuring accurate pressure measurements in a wide range of environments.
  • For pressure ranges > 3.5 MPa, the transmitter utilizes a sealed gauge, minimizing the impact of external ambient pressure fluctuations and enhancing its accuracy in high-pressure applications.

This flexible reference pressure configuration ensures the PX4 Pressure Transmitter delivers reliable and accurate pressure measurements across a broad spectrum of applications, making it a versatile and robust solution for demanding industrial environments.

This pressure transmitter series boasts an exceptional temperature resistance range of:

  • Compensation Temperature: -10…80°C
  • Application Temperature: -40…125°C
  • Storage Temperature: -40…125°C

This impressive temperature range makes the PX4 Pressure Transmitter an ideal choice for applications in harsh environments and demanding industrial settings. The transmitter’s robust design and high-quality materials enable it to withstand both cold and hot temperatures without compromising

Flexible Selections and Options

The PX4 Pressure Transmitter is a versatile and customizable pressure transmitter that can be tailored to meet the specific needs of a wide range of applications. It offers multiple options for reference pressure. The PX4 also features a variety of process and electrical connections, ensuring compatibility with a wide range of process systems.

Why Choose Hogller PX4?

In the unforgiving realm of industrial pressure measurement, the Hogller PX4 reigns supreme. Its micro-fused technology defies rupture, even under the most extreme conditions, while its temperature range of -40°C to 125°C encompasses even the most demanding applications. Constructed from premium stainless steel 17-4PH, this pressure transmitter stands as an unyielding sentinel against shock, vibration, and the unforgiving rigors of industry. Forget the uncertainties of unreliable pressure measurement. With the Hogller PX4, you’re armed with the confidence of knowing that your pressure data is accurate, precise, and unwavering, even in the face of extreme conditions.

Our Specifications

Our Specifications

Feature Value Code
Pressure Type Gauge G
Sealed Gauge S
Pressure Range 0 … 40 e.g. (0 … 40)
Unit mbar kPa
bar MPa
psi kgf/cm²
Power Supply 5 ± 0.1 VDC S04
8 … 33 VDC S09
11 … 33 VDC S14
Output Signal 4 … 20 mA / 2-wire C01
0 … 10 VDC / 3-wire V01
0.5 … 4.5 VDC / 3-wire V07
Accuracy ≤ ±0.5 %FS A5
≤ ±1 %FS A6
Process Connection G 1/2“ B, Male, std. EN 837 04
M20 x 1.5, Male, std. EN 837 05
G 1/4“ A, Male, std. ISO 1179-2 13
G 3/8“ A, Male, std. ISO 1179-2 14
1/4“ NPT, Male, std. ANSI/ASME B1.20.1 23
Snubber Without Snubber null
With Snubber S
Customized Pressure Channel C
Electrical Connection DIN EN 175301-803, Form C D2
M12x1, 4-pin, Mat. Steel M2
Packard Metri-Pack, 3-pin P1
Cable Outlet, Mat. PUR C2
Extension Cable Without Assorted Connector null
With Assorted Connector B1
Female Straight Connector M12x1, 4-pin Integrated with 2m Cable B2
Female Right Angle Connector M12x1, 4-pin Integrated with 2m Cable B3
n means cable length when electrical connection is C2 type (exc. L0 = 0.5 m) Ln
Material SS 17-4PH Diaphragm, SS 304 Pressure Port, SS 304 Housing 62
SS 17-4PH Diaphragm, SS 17-4PH Pressure Port, SS 304 Housing 66
Sealing Material Without Seal W
NBR N
FKM F

Stocked Products

Stocked Products

Part Number Pressure Range Output Signal Accuracy Process Connection
PX4-G-(0 ... 10)bar-S09-C01-13-D2-B1 (0 ... 10) bar 4 ... 20 mA / 2-wire ≤±1 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-G-(0 ... 16)bar-S09-C01-13-D2-B1 (0 ... 16) bar 4 ... 20 mA / 2-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-G-(0 ... 25)bar-S09-C01-13-D2-B1 (0 ... 25) bar 4 ... 20 mA / 2-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-G-(0 ... 30)bar-S09-C01-13-D2-B1 (0 ... 30) bar 4 ... 20 mA / 2-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 40)bar-S09-C01-13-D2-B1 (0 ... 40) bar 4 ... 20 mA / 2-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 60)bar-S09-C01-13-D2-B1 (0 ... 60) bar 4 ... 20 mA / 2-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 100)bar-S09-C01-13-D2-B1 (0 ... 100) bar 4 ... 20 mA / 2-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 160)bar-S09-C01-13-D2-B1 (0 ... 160) bar 4 ... 20 mA / 2-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 200)bar-S09-C01-13-D2-B1 (0 ... 200) bar 4 ... 20 mA / 2-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 250)bar-S09-C01-13-D2-B1 (0 ... 250) bar 4 ... 20 mA / 2-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 300)bar-S09-C01-13-D2-B1 (0 ... 300) bar 4 ... 20 mA / 2-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 350)bar-S09-C01-13-D2-B1 (0 ... 350) bar 4 ... 20 mA / 2-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 400)bar-S09-C01-13-D2-B1 (0 ... 400) bar 4 ... 20 mA / 2-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 600)bar-S09-C01-13-D2-B1 (0 ... 600) bar 4 ... 20 mA / 2-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 800)bar-S09-C01-04-D2-B1 (0 ... 800) bar 4 ... 20 mA / 2-wire ≤±0.5 %FS G 1/2“ B, Male, std. EN 837
PX4-S-(0 ... 1000)bar-S09-C01-04-D2-B1 (0 ... 1000) bar 4 ... 20 mA / 2-wire ≤±0.5 %FS G 1/2“ B, Male, std. EN 837
PX4-G-(0 ... 10)bar-S14-V01-13-D2-B1 (0 ... 10) bar 0 ... 10 VDC / 3-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-G-(0 ... 16)bar-S14-V01-13-D2-B1 (0 ... 16) bar 0 ... 10 VDC / 3-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-G-(0 ... 25)bar-S14-V01-13-D2-B1 (0 ... 25) bar 0 ... 10 VDC / 3-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 40)bar-S14-V01-13-D2-B1 (0 ... 40) bar 0 ... 10 VDC / 3-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 100)bar-S14-V01-13-D2-B1 (0 ... 100) bar 0 ... 10 VDC / 3-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 160)bar-S14-V01-13-D2-B1 (0 ... 160) bar 0 ... 10 VDC / 3-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 250)bar-S14-V01-13-D2-B1 (0 ... 250) bar 0 ... 10 VDC / 3-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 400)bar-S14-V01-13-D2-B1 (0 ... 400) bar 0 ... 10 VDC / 3-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *
PX4-S-(0 ... 600)bar-S14-V01-13-D2-B1 (0 ... 600) bar 0 ... 10 VDC / 3-wire ≤±0.5 %FS G 1/4“ A, Male, std. ISO 1179-2 *

Downloads

Datasheets

Hogller PX4 Series Datasheet (EN)

Related
Solutions

Related
Solutions

Enhance wind turbine performance with precision pressure transmitters for optimal hydraulic system monitoring. Maximize energy capture and ensure turbine safety with reliable pressure monitoring solutions.

Related
Series

Related
Series

HOH

Contact Us Today

To learn more about the Hogller PX1 series pressure transmitter or to request a quote, please contact us today.

PX4 Series