PX4 Series
- Type: Gauge, Sealed Gauge
- Range: 0 ... 10 bar to 0 ... 1000 bar
- Accuracy: ≤ ±0.5 %FS, ≤ ±1 %FS
- Output: 4 ... 20 mA, 0 ... 10 VDC, 0.5 ... 4.5 VDC, 0.5 ... 4.5 VDC Ratiometric
Applications
Machine tools, Hydraulics and pneumatics, Plant control and monitoring, Refrigeration systems, Pumps and compressors control, Energy management systems, HVAC systems
Describtion
Key
Features
Unmatched Overpressure and Burst Pressure Resistance
The PX4 Pressure Transmitter from Hogller features an advanced micro-fused technology that enables it to withstand extreme overpressure and burst pressure conditions. This technology is responsible for the transmitter’s ability to withstand up to 3xFS of overpressure, ensuring its reliability and safety in demanding applications This exceptional performance is achieved without compromising the transmitter’s accuracy and reliability.
Overpressure Resistance:
- For pressure ranges up to 50 bar: 3xFS
- For pressure ranges of 50 to 750 bar: 2xFS
- For pressure ranges of 750 to 1000 bar: 1.5xFS
Burst Pressure:
- ≤ 5xFS (maximum of 2000 bar for pressure ranges greater than 400 bar)
Unparalleled Vibration and Shock Resistance
The Hogller PX4 Pressure Transmitter is designed to withstand harsh environments, featuring exceptional vibration and shock resistance. It can tolerate a 20 g vibration within the frequency range of 20 Hz to 2000 Hz, ensuring its resilience in demanding applications.
The PX4 Pressure Transmitter also excels in shock resistance, capable of withstanding a 100 g shock with a duration of 6 ms. This exceptional shock resistance safeguards the transmitter from sudden impacts and abrupt pressure fluctuations, ensuring its reliable operation even in the most challenging environments.
The PX4 Pressure Transmitter’s unwavering performance under vibration and shock conditions is a testament to its exceptional design and engineering. These features make it an ideal choice for applications where the transmitter is exposed to harsh environments and sudden impacts.
Non-Oil-Filled Design for Enhanced Performance
The PX4 series pressure transmitter leverages a non-oil-filled design, eliminating the need for an internal sealing ring, thereby enhancing its reliability, simplifying maintenance, and expanding its compatibility with various applications. The wetted parts of the transmitter are meticulously crafted from stainless steel 17-4PH, a corrosion-resistant material that ensures the accuracy of pressure transmission. The isolation diaphragm, likewise, is made from the same material, maintaining pressure signal integrity.
The lack of oil filling in the transmitter eliminates the risk of oil leakage and contamination, further enhancing its reliability and safety. This all-metal sealing structure, coupled with the use of high-grade stainless steel materials, makes the PX4 Pressure Transmitter an ideal choice for applications where extreme environmental conditions and prolonged exposure to corrosive substances are a concern.
Pressure Reference Depending on Measuring Range
The PX4 pressure transmitter features a dual reference pressure setup, catering to the specific needs of applications with different measuring ranges.
- For pressure ranges ≤ 3.5 MPa, the transmitter employs a vented gauge, ensuring accurate pressure measurements in a wide range of environments.
- For pressure ranges > 3.5 MPa, the transmitter utilizes a sealed gauge, minimizing the impact of external ambient pressure fluctuations and enhancing its accuracy in high-pressure applications.
This flexible reference pressure configuration ensures the PX4 Pressure Transmitter delivers reliable and accurate pressure measurements across a broad spectrum of applications, making it a versatile and robust solution for demanding industrial environments.
Unparalleled Temperature Resistance
This pressure transmitter series boasts an exceptional temperature resistance range of:
- Compensation Temperature: -10…80°C
- Application Temperature: -40…125°C
- Storage Temperature: -40…125°C
This impressive temperature range makes the PX4 Pressure Transmitter an ideal choice for applications in harsh environments and demanding industrial settings. The transmitter’s robust design and high-quality materials enable it to withstand both cold and hot temperatures without compromising
Flexible Selections and Options
The PX4 Pressure Transmitter is a versatile and customizable pressure transmitter that can be tailored to meet the specific needs of a wide range of applications. It offers multiple options for reference pressure. The PX4 also features a variety of process and electrical connections, ensuring compatibility with a wide range of process systems.
Why Choose Hogller PX4?
In the unforgiving realm of industrial pressure measurement, the Hogller PX4 reigns supreme. Its micro-fused technology defies rupture, even under the most extreme conditions, while its temperature range of -40°C to 125°C encompasses even the most demanding applications. Constructed from premium stainless steel 17-4PH, this pressure transmitter stands as an unyielding sentinel against shock, vibration, and the unforgiving rigors of industry. Forget the uncertainties of unreliable pressure measurement. With the Hogller PX4, you’re armed with the confidence of knowing that your pressure data is accurate, precise, and unwavering, even in the face of extreme conditions.
Our Specifications
Our Specifications
Feature | Value | Code |
---|---|---|
Pressure Type | Gauge | G |
Sealed Gauge | S | |
Pressure Range | 0 … 40 | e.g. (0 … 40) |
Unit | mbar | kPa |
bar | MPa | |
psi | kgf/cm² | |
Power Supply | 5 ± 0.1 VDC | S04 |
8 … 33 VDC | S09 | |
11 … 33 VDC | S14 | |
Output Signal | 4 … 20 mA / 2-wire | C01 |
0 … 10 VDC / 3-wire | V01 | |
0.5 … 4.5 VDC / 3-wire | V07 | |
Accuracy | ≤ ±0.5 %FS | A5 |
≤ ±1 %FS | A6 | |
Process Connection | G 1/2“ B, Male, std. EN 837 | 04 |
M20 x 1.5, Male, std. EN 837 | 05 | |
G 1/4“ A, Male, std. ISO 1179-2 | 13 | |
G 3/8“ A, Male, std. ISO 1179-2 | 14 | |
1/4“ NPT, Male, std. ANSI/ASME B1.20.1 | 23 | |
Snubber | Without Snubber | null |
With Snubber | S | |
Customized Pressure Channel | C | |
Electrical Connection | DIN EN 175301-803, Form C | D2 |
M12x1, 4-pin, Mat. Steel | M2 | |
Packard Metri-Pack, 3-pin | P1 | |
Cable Outlet, Mat. PUR | C2 | |
Extension Cable | Without Assorted Connector | null |
With Assorted Connector | B1 | |
Female Straight Connector M12x1, 4-pin Integrated with 2m Cable | B2 | |
Female Right Angle Connector M12x1, 4-pin Integrated with 2m Cable | B3 | |
n means cable length when electrical connection is C2 type (exc. L0 = 0.5 m) | Ln | |
Material | SS 17-4PH Diaphragm, SS 304 Pressure Port, SS 304 Housing | 62 |
SS 17-4PH Diaphragm, SS 17-4PH Pressure Port, SS 304 Housing | 66 | |
Sealing Material | Without Seal | W |
NBR | N | |
FKM | F |
Stocked Products
Stocked Products
Part Number | Pressure Range | Output Signal | Accuracy | Process Connection |
---|---|---|---|---|
PX4-G-(0 ... 10)bar-S09-C01-13-D2-B1 | (0 ... 10) bar | 4 ... 20 mA / 2-wire | ≤±1 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-G-(0 ... 16)bar-S09-C01-13-D2-B1 | (0 ... 16) bar | 4 ... 20 mA / 2-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-G-(0 ... 25)bar-S09-C01-13-D2-B1 | (0 ... 25) bar | 4 ... 20 mA / 2-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-G-(0 ... 30)bar-S09-C01-13-D2-B1 | (0 ... 30) bar | 4 ... 20 mA / 2-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 40)bar-S09-C01-13-D2-B1 | (0 ... 40) bar | 4 ... 20 mA / 2-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 60)bar-S09-C01-13-D2-B1 | (0 ... 60) bar | 4 ... 20 mA / 2-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 100)bar-S09-C01-13-D2-B1 | (0 ... 100) bar | 4 ... 20 mA / 2-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 160)bar-S09-C01-13-D2-B1 | (0 ... 160) bar | 4 ... 20 mA / 2-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 200)bar-S09-C01-13-D2-B1 | (0 ... 200) bar | 4 ... 20 mA / 2-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 250)bar-S09-C01-13-D2-B1 | (0 ... 250) bar | 4 ... 20 mA / 2-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 300)bar-S09-C01-13-D2-B1 | (0 ... 300) bar | 4 ... 20 mA / 2-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 350)bar-S09-C01-13-D2-B1 | (0 ... 350) bar | 4 ... 20 mA / 2-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 400)bar-S09-C01-13-D2-B1 | (0 ... 400) bar | 4 ... 20 mA / 2-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 600)bar-S09-C01-13-D2-B1 | (0 ... 600) bar | 4 ... 20 mA / 2-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 800)bar-S09-C01-04-D2-B1 | (0 ... 800) bar | 4 ... 20 mA / 2-wire | ≤±0.5 %FS | G 1/2“ B, Male, std. EN 837 |
PX4-S-(0 ... 1000)bar-S09-C01-04-D2-B1 | (0 ... 1000) bar | 4 ... 20 mA / 2-wire | ≤±0.5 %FS | G 1/2“ B, Male, std. EN 837 |
PX4-G-(0 ... 10)bar-S14-V01-13-D2-B1 | (0 ... 10) bar | 0 ... 10 VDC / 3-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-G-(0 ... 16)bar-S14-V01-13-D2-B1 | (0 ... 16) bar | 0 ... 10 VDC / 3-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-G-(0 ... 25)bar-S14-V01-13-D2-B1 | (0 ... 25) bar | 0 ... 10 VDC / 3-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 40)bar-S14-V01-13-D2-B1 | (0 ... 40) bar | 0 ... 10 VDC / 3-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 100)bar-S14-V01-13-D2-B1 | (0 ... 100) bar | 0 ... 10 VDC / 3-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 160)bar-S14-V01-13-D2-B1 | (0 ... 160) bar | 0 ... 10 VDC / 3-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 250)bar-S14-V01-13-D2-B1 | (0 ... 250) bar | 0 ... 10 VDC / 3-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 400)bar-S14-V01-13-D2-B1 | (0 ... 400) bar | 0 ... 10 VDC / 3-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
PX4-S-(0 ... 600)bar-S14-V01-13-D2-B1 | (0 ... 600) bar | 0 ... 10 VDC / 3-wire | ≤±0.5 %FS | G 1/4“ A, Male, std. ISO 1179-2 * |
Downloads
Datasheets
Hogller PX4 Series Datasheet (EN)
Requests
Catalogs
Related Solutions
Related Solutions
Related Series
Related Series
- Type: Absolute, Gauge, Sealed Gauge
- Range: 0 ... 100 mbar to 0 ... 250 bar
- Accuracy: ≤ ±0.25 %FS, ≤ ±0.5 %FS, ≤ ±1 %FS
- Type: Absolute, Gauge
- Range: -1...0 to -1...60 bar, 0...600 mbar to 0...2000 bar
- Accuracy: ≤ ±0.5 %FS